Update time:2025-11-03 Edit:admin Views:233

Semiconductor Cooling and Thermal Management
1. Data Center Servers/AI Supercomputing/GPU Chips
Immersion Cooling: Fluorinated liquids (such as FC-40, Novec-7200) directly immerse server hardware, achieving efficient heat dissipation through high thermal conductivity (close to that of water) and low surface tension. This results in energy savings of over 85% compared to air cooling, with a PUE value below 1.1.
Dynamic Cooling: In chip aging tests, fluorinated liquids rapidly absorb transient heat loads, ensuring test accuracy and equipment stability.
2. Semiconductor Chillers
Used as a refrigerant for temperature control (±0.1℃ accuracy) in equipment such as lithography and etching machines, its thermal stability (liquid range -57~165℃) ensures reliable operation under extreme temperatures.
3. Plasma Etching and CVD Equipment
Electrode Cooling: Fluorinated liquids (such as FC-40) cool electrodes through single-phase or two-phase circulation, preventing equipment deformation caused by high-temperature plasma. Their non-conductive properties prevent short circuits.
4. Reaction Chamber Temperature Control: Maintains uniform reaction temperature in chemical vapor deposition (CVD), and material compatibility (compatible with metals/plastics) reduces the risk of equipment corrosion.
5. Ion Implanters and Testing Equipment
Fluorinated liquids (such as Novec-7100) are used to cool high-energy ion beam generation components; their chemical inertness prevents reactions with sensitive elements.
6. Single/Dual-Phase Cooling Systems
Single-Phase System: FC-40, with its narrow boiling range (compositional stability) and high dielectric strength, is used for semiconductor cold plate cooling, reducing fluid loss.
Dual-Phase System: Novec-7200 provides passive heat dissipation through an evaporation-condensation cycle (requiring no additional energy consumption), suitable for high-density GPU mining rigs and AI chip cooling.
7. Heat Pipe and Microchannel Cooling
Low surface tension allows fluorinated liquids to penetrate microscopic gaps, achieving precise chip-level heat dissipation coverage.
Furthermore, Key Features and Advantages:
1. Non-conductive: High dielectric strength (e.g., FC-40 dielectric strength >40kV) prevents current leakage and ensures equipment safety.
2. Thermally stable: Wide operating temperature range (-90~200℃) adapts to extreme environments; boiling point up to 165℃ (FC-40) ensures no decomposition at high temperatures.
3. Material compatibility: Compatible with metals, plastics, and sealing materials; no corrosion or swelling during long-term use.
Previous:LED display screen and lighting
Next:consumer electronics